• CESW-01-2-C-1-2

CESW Resistance Type Oil Electric Lubricator

  • Proportional Oil Quantity 
  • Automatic Lubrication Controlled by Timer
  • Two Operation Modes Available 

Please select the specifications you need.:

*Model
*Tank Capacity (Material)
*ACTx INT
*Voltage
*Discharge Bore
*Operation Mode
Remarks
  1. The operation and interval time adjusters are on the control box of CESW. There are operation (ACT) and interval (INT) indicators on the control box.
  2. There are two operation modes after the power of CESW is on. The standard mode is turn-on-interval.
    ● Turn-on-feeding: Operation time starts first after the power is on.
    ● Turn-on-interval: Interval time starts first after the power is on.
  3. Turn-on-interval model has a memory function. If the power is suddenly off during the interval time, CESW will continue to operate from the remaining interval time after restarting, which can effectively avoid over-lubrication.
  4. CESW has a NC contact float switch that detects the oil level automatically and sends signals when the oil level is low.
  5. CESW has a buzzer that sends an alarm sound when the oil level is low.
  6. CESW has a feed-oil button (F button), which can be used as manual oil feeding for less than 3 minutes to avoid overloading the motor.
  7. CESW has a thermal control that shuts down the motor for about 5 minutes when the motor is overheated.

cesw Dimensional Drawing


◆ Dimensional Data

Tank Capacity Tank Material Length (mm) Width (mm) Height (mm) Fixed Hole Distance (mm) N.W. (kg)
2L Resin 213 142 244 177 3.00
2L Alum. 221 156 234 95x200 4.15
3L Resin 227 167 248 205 3.45
4L Resin 277 162 259 250 3.90
4L Alum. 297 173 253 95x280 4.90
8L Iron 355 201 270 95x338 7.55

◆ Technical Data

Operation Time 3-60 sec
Interval Time 1-60 min, 1-180 min, 1-12hr, 1-72hr
Motor Power 12±3W
Voltage 110V 220V
Ampere 1.5A 0.7A
Hertz 60Hz 50Hz, 60Hz
Max. Discharge Volume 130cc/min
Max. Operating Pressure 8kgf/c㎡
Discharge Bore Ø4 , Ø6
Float Switch NC Contact
Suitable Viscosity Oil, 32-68 cSt@40oC

◆ Wiring Diagram

Abnormal Output Ground Power
NO(A) NC(B) COM GND(P.E) POWER


◆ Order Code

Model Tank Capacity(Material) ACT x INT Voltage Discharge Bore Operation Mode
CESW 01 2 C 1 2
01 2L (Resin) 1 60 sec x 60 min A 110V, 60Hz 0 Ø4 1 Turn-on-Feeding
02 2L (Alum.) 2 60 sec x 180 min B 220V, 50Hz 1 Ø6 2 Turn-on-Interval
03 3L (Resin) 3 60 sec x 12 hours C 220V, 60Hz 2 Ø4 W/Pressure Gauge
04 4L (Resin) 4 60 sec x 72 hours 3 Ø6 W/Pressure Gauge
05 4L (Alum.)
08 8L (Iron)